ASTM E331-00 PDF

The ASTM E (Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure. Imison. John H. Waskow, P.E.. Architectural Testing, Inc. Test Method: ASTM E , Test Method for Water Penetration of Exterior Windows, Curtain Walls. Purchase your copy of ASTM E – 00() as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards.

Author: Faushura Maull
Country: Laos
Language: English (Spanish)
Genre: Sex
Published (Last): 13 October 2013
Pages: 138
PDF File Size: 4.60 Mb
ePub File Size: 3.60 Mb
ISBN: 563-7-43480-137-2
Downloads: 47137
Price: Free* [*Free Regsitration Required]
Uploader: Mikajinn

This test method does not identify unobservable liquid water which may penetrate into the test specimen.

ASTM E | Water Penetration Testing

For specific hazard statements, see 7. The ASTM E Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference is a testing standard that describes the procedures to determine the water penetration e313-00 of windows, curtain walls, skylights, and doors when water is applied using a calibrated spray apparatus while simultaneously applying uniform static pressure to opposite sides of the test specimen.

Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset. Historical Version s – view previous versions of standard.

ASTM International – Standard References for ASTM E – 00()

Give us a call to discuss your next project. The air-pressure differences acting across a building envelope vary greatly. These factors should be fully considered prior to specifying the test pressure difference to be used.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This test method does not address these issues. In service, the performance will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, etc.

  AS 3439.1 PDF

The ASTM E testing is performed by applying water to the exterior of the test specimen while lowering the pressure inside by means of an air chamber built on the inside or opposite side of the test specimen.

ASTM E331 – 00(2016)

Failures during quality assurance new construction testing can result in unnecessary delays that impact your bottom line. Link to Active This link will always route to the current Active version of the standard. Some designs are more sensitive than others to this upward moving water. The testing pressure differential is usually determined by the testing specifier.

BDG awtm professional testing equipment that is calibrated to each specific testing standard for accurate results. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass.

Referenced Documents purchase separately The documents listed below are ast within the subject standard but are not provided as part of the standard. In applying the results of tests by this test method, note that the aatm of a wall or its components, or both, may be a function of proper installation and adjustment. The water spray system has nozzles spaced on a grid to deliver water so that the test specimen is wet uniformly, includingthose areas vulnerable to water penetration.

  DYNACORD LX3000 PDF

The calibrated e331-000 apparatus spray-rack system delivers water to the test specimen at a rate of 5. This allows us to not only properly test fenestrations on new construction projects, but also pinpoint the cause of any test failures and provide accurate recommendations to achieve successful testing results.

BDG has extensive knowledge of most building systems and specializes in ast water intrusion investigations. Building Diagnostics Group, Inc. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

Our field consultants are properly trained and knowledgeable of all testing standards. Most generic specifications call for a minimum testing pressure of 6. If you are looking for a reputable second or third-party testing company to perform accurate professional testing, provide concise reports, and help you through the entire process, contact BDG today. We provide testing services throughout the United States from our headquarters located in Atlanta, GA.

It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water.

MISSION Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset.